Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Braz. J. Pharm. Sci. (Online) ; 56: e18420, 2020. tab, graf
Article in English | LILACS | ID: biblio-1249160

ABSTRACT

A new stability-indicating liquid chromatographic method was developed and validated for the estimation of glycopyrrolate in pharmaceutical formulations. A contemporary approach to analytical life-cycle management was followed to develop a robust and reliable chromatographic method. Scouted method variables such as % methanol, the strength of tetra butyl ammonium hydrogen sulfate and mobile phase flow rate were optimized using the design of experiment approach and their effect on critical quality attributes was studied. The critical quality attributes viz. retention time, theoretical plate count and symmetry factor were highly influenced by the three critical method variables. Optimum chromatography was attained on a C-18 column with a mobile phase methanol: 10 mM tetra butyl ammonium hydrogen sulfate (80:20, v/v) flowing at 1.0 mL.min-1. Chromatographic method specificity was ensured by degrading the drug forcefully. Validation studies postulated method acceptability and suitability for estimating glycopyrrolate in both bulk as well as injection formulation. Results for parameters viz. linearity (5-250 µg.mL-1), accuracy (>99%) and precision (<2%) advocated method reliability. Overall the method was reliable and of optimum quality and, possess the potential of application in routine and bio-analytical purposes


Subject(s)
Chromatography/instrumentation , Chromatography, Liquid/methods , Validation Study , Glycopyrrolate/agonists , Pharmaceutical Preparations , Sensitivity and Specificity , Characidae/classification , Injections/adverse effects , Methods
2.
Braz. j. pharm. sci ; 49(3): 475-490, July-Sept. 2013. ilus, tab
Article in English | LILACS | ID: lil-689901

ABSTRACT

A novel, simple, accurate and precise RP-HPLC method for simultaneous determination of levosalbutamol sulfate and theophylline has been developed and validated. Separation was achieved on a Phenomenex; C18 column (250 mm × 4.6 mm i.d., 5 µm) using methanol: 10 mM TBAHS(tetrabutyl ammonium hydrogen sulfate) (50:50, v/v) as mobile phase at flow rate of 1.0 mL.min-1. The UV detection wavelength was 274 nm. The linearity is obeyed over a concentration range of 0.5-150 µg.mL-1 with correlation coefficient of 0.999 for both the drugs. The proposed method was validated by determining accuracy, precision, stability and system suitability parameters. The method was found to be robust. Specificity of the method was determined by subjecting the drugs to various stress conditions like acid, alkali, oxidation, thermal and photolytic degradation. The method was used successfully for the simultaneous determination of levosalbutamol sulfate and theophylline in syrup dosage form.


Desenvolveu-se e validou-se método de RP-HPLC novo, simples, exato e preciso de determinação simultânea do sulfato de levossalbutamol e teofilina.. A separação foi efetuada em uma coluna Phenomenex; C18 (250 mm x 4,6 mm d.i., 5 µm) utilizando metanol: TBAHS (hidrogenossulfato de tetrabutilamônio) 10 mM (50:50, v/v) como fase móvel, com fluxo de 1,0 mL.min-1. O comprimento de onda de detecção no UV foi 274 nm. Observou-se linearidade na faixa de concentração de 0,5-150 µg mL-1, com coeficiente de correlação de 0,999 para ambos os fármacos. O método proposto foi validado determinando-se exatidão, precisão, estabilidade e parâmetros de adequação do sistema. O método mostrou-se robusto. A especificidade do método foi determinada submetendo os fármacos a várias condições de estresse, como ácido, álcali, oxidação, degradação térmica e fotolítica. O método foi usado com sucesso para a determinação simultânea do sulfato de levossalbutamol e teofilina na forma de xarope.


Subject(s)
Theophylline/analysis , Chromatography, High Pressure Liquid/methods , Levalbuterol/analysis , Dosage Forms
SELECTION OF CITATIONS
SEARCH DETAIL